Toro Max: Error 11

Error 11 indicates the printer can’t detect the notch/hole or black mark on the back of the label.

DuraLabel printers use information programmed on the smart chip to determine the location of a notch or black mark on the supply in order to align with preprinted objects or die-cut labels. If the prints/cuts are misaligned or the printer errors, the printer likely needs calibrated, the media sensor needs adjusted or the driver settings are incorrect.

Troubleshooting:

  1. Power cycle the printer to ensure that it is not stuck in error status.
  2. Ensure that the adjustable media sensor is aligned with the notch in the supply or the black mark on the back of the liner.
  3. Confirm the cutter is set to labels with notches or black marks in the driver or onboard the printer.
  4. Calibrate:
    1. Open and close the lid, printer should pop up with a calibration button.
    2. If not, navigate to Printer Settings, Preferences, Calibrate Supply.
  5. Ensure that the label size in LabelForge Pro matches the label size on the supply.
    • The printer will error if it doesn’t see the black mark or notch within 13mm of the end of print job.
  6. Determine if the smart chip has the correct media/cut format and is the original end cap for that supply. End caps transferred from other supply frequently cause this error.
  7. If error continues, contact Tech Support or your Account Manager for further instructions.